I replaced OEM WARRANTY Bryant Evolution Connex communicating thermostat.

Near Highland Woods Blvd, New Albany, OH 43054
New Albany, OH - I replaced OEM WARRANTY Bryant Evolution Connex communicating thermostat.
Hunter P.

Hunter P.

I ran diagnostic performed check on furnace adjusted st stage gas pressure to 1.65, was at 1.8. Cleaned flame sensor. Sytem correctly went into high fire after 20 minutes of running low fire.

Near Wiveliscombe, New Albany, OH 43054
New Albany, OH - I ran diagnostic performed check on furnace adjusted st stage gas pressure to 1.65, was at 1.8. Cleaned flame sensor. Sytem correctly went into high fire after 20 minutes of running low fire.
Greg N.

Greg N.

Found nest thermostat sending voltage to both heating and cooling equipment bad thermostat. replaced thermostat with one provided with install last winter.

Near Alpath Rd, New Albany, OH 43054
New Albany, OH - Found nest thermostat sending voltage to both heating and cooling equipment bad thermostat. replaced thermostat with one provided with install last winter.
Greg N.

Greg N.

Replaced inducer cap on 2004 Bryant 90% and system fired up no problem. Quoted customer for replacement 90% OEM Inducer Motor.

Near Albany Crest Ave, New Albany, OH 43054
New Albany, OH - Replaced inducer cap on 2004 Bryant 90% and system fired up no problem. Quoted customer for replacement 90% OEM Inducer Motor.
Greg N.

Greg N.

I replaced an OEM Inducer Motor for a 2006 Comfortmaker gas furnace. Everything running properly at time of departure.

Near Fodor Rd, New Albany, OH 43054
New Albany, OH - I replaced an OEM Inducer Motor for a 2006 Comfortmaker gas furnace. Everything running properly at time of departure.
Hunter P.

Hunter P.

Did not quote replacement as current unit is only 6 years old. Explained to customer I want to work on the furnace and get it running better. Office will schedule a future visit.

Near Wiveliscombe, New Albany, OH 43054
New Albany, OH - Did not quote replacement as current unit is only 6 years old. Explained to customer I want to work on the furnace and get it running better. Office will schedule a future visit.
Greg N.

Greg N.

Trap not secure. Switch closes at 1.33 and draft is only 1.35 quoted heat exchanger 90% trane.

Near New Albany Links Dr, New Albany, OH 43054
New Albany, OH - Trap not secure. Switch closes at 1.33 and draft is only 1.35 quoted heat exchanger 90% trane.
Jeff S.

Jeff S.

I installed Carrier 80% 90,000 BTU Gas Furnace Model # 58SBOA090E171214 CS 3.5T 17"

Near Albany Park Dr, New Albany, OH 43054
New Albany, OH - I installed Carrier 80% 90,000 BTU Gas Furnace
Model # 58SBOA090E171214 CS 3.5T 17"
Hunter P.

Hunter P.

I installed a new iWave-R Air Cleaner

Near Galdino Dr, New Albany, OH 43054
New Albany, OH - I installed a new iWave-R Air Cleaner