Christopher M.

Christopher M.

Performed tuneup and safety check on 2015 Goodman AC. All is working well at this time.

Near Marshview Dr, Hilliard, OH 43026
Hilliard, OH - 	Performed tuneup and safety check on 2015 Goodman AC. All is working well at this time.
Hunter P.

Hunter P.

Upon arrival found water on basement floor around 2020 Carrier Gas Furnace 96% Variable Speed Two-Stage 60,000 BTU furnace. Opened burner door and found rubber elbow was disconnected from condensate trap inside furnace. Elbow and drain have a coating of oil inside them. Removed both and cleaned oil from parts. Also ruffed the surfaces up on the elbow, drain line and drain trap. Oil is coming from the heat exchanger. Oil is used to make the heat exchanger at the factory. No water leaking at this time. Normal operation

Near Pinefield Dr, Hilliard, OH 43026
Hilliard, OH - Upon arrival found water on basement floor around 2020 Carrier Gas Furnace 96% Variable Speed Two-Stage 60,000 BTU furnace.
Opened burner door and found rubber elbow was disconnected from condensate trap inside furnace.
Elbow and drain have a coating of oil inside them. Removed both and cleaned oil from parts. Also ruffed the surfaces up on the elbow, drain line and drain trap.
Oil is coming from the heat exchanger. Oil is used to make the heat exchanger at the factory.
No water leaking at this time. Normal operation
Noah B.

Noah B.

Furnace tune up and safety inspection on 2018 Carrier gas unit.

Near Brittany Oaks Blvd, Hilliard, OH 43026
Hilliard, OH - Furnace tune up and safety inspection on 2018 Carrier gas unit.
Greg N.

Greg N.

Diagnostic service call on 2003 Trane furnace. Condensation drain line was clogged, due to water softener tubes draining into the condensation line drain, it would overflow and leak down into blower housing, replaced condensation drain line, pulled and cleaned blower housing, furnace operational at departure.

Near Scioto Darby Rd, Hilliard, OH 43026
Hilliard, OH - Diagnostic service call on 2003 Trane furnace.  Condensation drain line was clogged, due to water softener tubes draining into the condensation line drain, it would overflow and leak down into blower housing, replaced condensation drain line, pulled and cleaned blower housing, furnace operational at departure.
Noah B.

Noah B.

Hilliard heating and cooling service

Near Hilliard, OH 43026
Noah B.

Noah B.

Upon arrival I found the furnace has a cracked heat exchanger I provided the customer with an estimate for a new furnace.

Near Jasonway Dr, Hilliard, OH 43026
Hilliard, OH -  Upon arrival I found the furnace has a cracked heat exchanger  I provided the customer with an estimate for a new  furnace.
Noah B.

Noah B.

Diagnostic service call on Trane furnace.

Near Pheasant Field Dr, Hilliard, OH 43026
Hilliard, OH - Diagnostic service call on Trane furnace.
Noah B.

Noah B.

Diagnostic service call on 2019 Carrier Furnace

Near Pheasant Field Dr, Hilliard, OH 43026
Noah B.

Noah B.

Tech returned to replace under warranty limit switch on 2019 Carrier Furnace.

Near Westrock Dr, Hilliard, OH 43026
Noah B.

Noah B.

Hilliard heating and cooling weekend service.

Near Janes Way, Hilliard, OH 43026