Great service




Review of Grove City Heating & Air

They arrived on a Sunday and fixed the issue in 20 minutes!


Noah B.

Noah B.

I completed an install of a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner

Near Princeton Ln, Groveport, OH 43125
Groveport, OH - I completed an install of a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner
Greg N.

Greg N.

I performed a diagnostic on a Goodman gas furnace. I found that the limit was stuck so I fixed that and quoted the customer replacement cost if it happens again. System was fully operational upon my departure.

Near Elm St, Groveport, OH 43125
Groveport, OH - I performed a diagnostic on a Goodman gas furnace.  I found that the limit was stuck so I fixed that and quoted the customer replacement cost if it happens again.  System was fully operational upon my departure.
Noah B.

Noah B.

Upon inspection, I found the furnace was very old, rusted, and in poor condition. I informed the customer certain parts would need to be replaced just to fully diagnose the issues, and there is no guarantee those repairs will provide heat. Went over options with customer and they have opted to replace furnace. System is not operational upon departure.

Near Bixwood Ct S, Groveport, OH 43125
Groveport, OH - Upon inspection, I found the furnace was very old, rusted, and in poor condition. I informed the customer certain parts would need to be replaced just to fully diagnose the issues, and there is no guarantee those repairs will provide heat. Went over options with customer and they have opted to replace furnace. System is not operational upon departure.
Greg N.

Greg N.

I performed a diagnostic on a 2002 Bryant gas furnace that is not igniting. I observed a bad igniter and replaced it. I also cleaned the trap and flame sensor. The system is operational at this time.

Near Highland Bluff Dr, Groveport, OH 43125
Groveport, OH - I performed a diagnostic on a 2002 Bryant gas furnace that is not igniting. I observed a bad igniter and replaced it. I also cleaned the trap and flame sensor. The system is operational at this time.
Hunter P.

Hunter P.

Upon inspection, I found the cause of the furnace overheating was the filter hadn't been changed in months. I removed the filter and cycled the system to ensure everything was working correctly. System is operational upon departure.

Near Walnut St, Groveport, OH 43125
Groveport, OH - Upon inspection, I found the cause of the furnace overheating was the filter hadn't been changed in months. I removed the filter and cycled the system to ensure everything was working correctly. System is operational upon departure.
Hunter P.

Hunter P.

I replaced the control board and collector box. I cycled the system to ensure functionality. System is operational upon departure.

Near Lesleh Ave, Groveport, OH 43125
Groveport, OH - I replaced the control board and collector box. I cycled the system to ensure functionality. System is operational upon departure.
Hunter P.

Hunter P.

I found the pressure switch needed replaced. I will have the office order the part and will come back out to replace once the part comes in. System is not operational upon departure.

Near Nutmeg Pl, Groveport, OH 43125
Groveport, OH - I found the pressure switch needed replaced. I will have the office order the part and will come back out to replace once the part comes in. System is not operational upon departure.
Hunter P.

Hunter P.

I found that the noise coming from the heat pump is from when the systems reversing valves changes the flow of refrigerant when the defrost is energized and is normal. I suggest using a less restrictive filter and I replaced the blower capacitor. 2016 Trane electric unit is operating as designed at departure.

Near Platte Ave, Groveport, OH 43125
Groveport, OH - I found that the noise coming from the heat pump is from when the systems reversing valves changes the flow of refrigerant when the defrost is energized and is normal. I suggest using a less restrictive filter and I replaced the blower capacitor. 2016 Trane electric unit is operating as designed at departure.
Greg N.

Greg N.

Access to this Carrier rooftop unit will require a 28 ft extension ladder. We will be back out tomorrow with ladder to safely access the roof.

Near Founders Dr, Groveport, OH 43125
Groveport, OH - Access to this Carrier rooftop unit will require a 28 ft extension ladder. We will be back out tomorrow with ladder to safely access the roof.
Greg N.

Greg N.

I performed a tune up on a Carrier 80% 90,000 BTU Gas Furnace. Everything is working within manufacturers specifications at this time.

Near Vermilion Ave, Groveport, OH 43125
Groveport, OH - I performed a tune up on a  Carrier 80% 90,000 BTU Gas Furnace. Everything is working within manufacturers specifications at this time.