Christopher M.

Christopher M.

Customer Wants us to install their ECOBEE Tstat. Wired furnace downstairs. I Replaced thermostat. All functions mechanically turn on.

Near Carnoustie Ct, Dublin, OH 43017
Dublin, OH - Customer Wants us to install their ECOBEE Tstat. Wired furnace downstairs. I Replaced thermostat. All functions mechanically turn on.
Greg N.

Greg N.

I Level outdoor condenser

Near Erie Ct, Dublin, OH 43017
Dublin, OH - I  Level outdoor condenser
Christopher M.

Christopher M.

Customer had reset the unit and it had started working a little better on the main floor.

Near Blessington Ct, Dublin, OH 43017
Dublin, OH - Customer had reset the unit and it had started working a little better on the main floor.
Greg N.

Greg N.

I replaced the OEM Condenser Fan Motor on the 2008 Lennox.

Near Old Oak Ln, Dublin, OH 43017
Dublin, OH - I replaced the OEM Condenser Fan Motor on the 2008 Lennox.
Christopher M.

Christopher M.

Performing our Five Star Tune-Up & Safety Check on a 2013 Lennox . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Wilton Chase St, Dublin, OH 43017
Dublin, OH - Performing our Five Star Tune-Up & Safety Check on a 2013 Lennox . All readings were within manufacturer's specifications, unit operating properly at this time.
Hunter P.

Hunter P.

Once coil melted checked refrigerant pressures, found pressures very low. System holds 4.10 lbs factory charged. Also found plugged condenser coils on the back side of the unit. cleaned condenser coils. While turning disconnect off noticed a loud noise coming from the compressor. Found capacitor out of spec on the fan side and at the max tolerance on the compressor side. Also found contactor humming and contacts pitted.

Near Wexler Rd, Dublin, OH 43016
Dublin, OH - Once coil melted checked refrigerant pressures, found pressures very low. System holds 4.10 lbs factory charged. Also found plugged condenser coils on the back side of the unit. cleaned condenser coils. While turning disconnect off noticed a loud noise coming from the compressor. Found capacitor out of spec on the fan side and at the max tolerance on the compressor side. Also found contactor humming and contacts pitted.
Christopher M.

Christopher M.

Scheduled Maintenance on Carrier "Infinity Series" 19 SEER Variable-Speed 3 Ton Air Conditioner

Near Bantry Ct, Dublin, OH 43016
Dublin, OH - Scheduled Maintenance on Carrier "Infinity Series" 19 SEER Variable-Speed 3 Ton Air Conditioner
Christopher M.

Christopher M.

Performing our Five Star Tune-Up & Safety Check on a 2009 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Craigston Ct, Dublin, OH 43017
Dublin, OH - Performing our Five Star Tune-Up & Safety Check on a 2009 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.
Noah B.

Noah B.

problem is with unit #6 per customer icing up system low, has a leak. gave customer options. Customer opted to charge and seal added 6#-r-22 and sealant, pressures 62/198 now cooling.

Near Shamrock Ct, Dublin, OH 43016
Dublin, OH - problem is with unit #6 per customer icing up system low, has a leak. gave customer options. Customer opted to charge and seal added 6#-r-22 and sealant, pressures 62/198 now cooling.
Hunter P.

Hunter P.

Provided an estimate for ductless minisplit system for Dublin customer.

Near Brodie Blvd, Dublin, OH 43017
Dublin, OH - Provided an estimate for ductless minisplit system for Dublin customer.